DTX CableAnalyzer Series
Specifikace
Cable Types Standard Link Interface Adapters |
Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:
|
Test Standards |
|
Speed of Autotest |
Full 2-way Autotest of Category 6
Twisted-Pair links in 9 seconds |
Supported Tests Parameters |
(The selected test standard determines the test parameters and the frequency range of the tests) Wire Map |
Cable Tone Generator |
Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz |
Display |
3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight. |
Input Protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage. |
Case |
High impact plastic with shock absorbing overmold |
Dimensions |
Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal |
Weight |
2.4 lb (1.1 kg), nominal (without adapter or module) |
Operating Temperature |
32°F to 104°F (0°C to 40°C) |
Storage Temperature |
-4°F to 104°F (-20°C to 60°C) |
Operating relative humidity (% RH without condensation) |
32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 % |
Vibration |
Random, 2 g, 5 Hz -500 Hz |
Shock |
1 m drop test with and without module and adapter attached |
Safety |
CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2 |
Pollution degree |
Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999" |
Altitude |
Operating: 4000 m; Storage: 12000 m |
EMC |
EN 61326-1 |
Power |
Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh
|
Languages Supported |
English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese, Traditional Chinese, Korean, Russian, Czech, Polish, Swedish, Hungarian. |
Calibration |
Service center calibration period is 1 year |
Performance Specifications |
Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance. |
Baseline accuracy |
The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3 over the frequency range supported by the tester. |
Category 6A/Class EA link test modes (and lower link categories) |
DTX CableAnalyzer far exceeds Level III requirements of ANSI/TIA-1152 and IEC 61935-1/Ed.3 |
Class F link test modes |
DTX-1800 is meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3. |
Length for Twisted Pair Cabling |
(Length specs do not include the uncertainty of the cable's NVP Value) |
Parameter |
Single-ended Test |
Range |
800 m (2600 ft) - Single-ended Test |
Resolution |
0.1 m or 1 ft - Single-ended Test |
Accuracy |
± (1m 4%) - Single-ended Test |
Delay Skew |
|
Parameter |
Twisted Pair Cabling |
Range |
0 ns to 100 ns |
Resolution |
1 ns |
Accuracy |
± 10 ns |
DC Loop Resistance Test |
|
Parameter |
Twisted Pair Cabling |
Range |
O Ω to 53Ω |
Resolution |
0.1 Ω |
Accuracy |
± (1 Ω 1%) |
Overload Recovery Time |
Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage. |