Specifikace CertiFiber® Max

Technické údaje

Produkt podporuje měření útlumu, výkonu i délky pro single-mode vlákna s přesností ±0,10 dB (výkon) a délkou až do 25 km s nepřesností ±1 m + 1 %

Multi-Fiber Optical Power Meter (per module) 
Specifications apply at 23°C, unless otherwise noted.  
Parameter Single-mode
Included UniPort Adapter Non-contact MPO 12-fiber pinned
Optional Uniport Adapters MPO 12/16/24 and MMC 16/24 pinned or unpinned
Detector Type 16 large core fibers coupled to 16 InGaAs photodiodes. 
Supported Fiber Type  Single-mode 9/125 µm
Calibrated Wavelengths 1310 nm, 1550 nm
Power Measurement Linearity1 ±0.10 dB
Power Measurement Repeatability1,2 ±0.02 dB
Power Measurement Reproducibility1,3 ±0.1 dB
Power Measurement Uniformity 4 ± 0.1dB
Loss Measurement Budget5 10 dB
Re-calibration Period  1 year
1. For the measurement range -10 dBm to -20 dBm. All photodiodes, over the measurement range. After a 5-minute warmup. 
2. Maximum variation of power measurements when the measurement is repeated multiple times (i.e. 5 times) without disturbing the optical connector during 5 seconds at -12-dBm SM. 
3. Maximum variation of power measurements when the measurement is repeated multiple times (i.e. 5 times) when the optical connector is disconnected and reconnected between repeated measurements at - 12-dBm SM. 
4. Maximum variation between any one detector when compared to any of the other detectors, including the optical power meter duplex port at -20dBm SM. 
5. Loss measurement budget specification provides flexibility within the power measurement range, for example, -10 dBm to -20 dBm for single-mode.
Multi-Fiber Optical Sources (per module)
Specifications apply at 23°C, unless otherwise noted.
Output port  MPO 16 pinned
Fiber Type 9/125 µm
Central Wavelengths (nm) 1310 ± 20 
1550 ± 20
Emitter Type Fabry-Perot laser
Spectral Width (nm)1 ≤5 (1310 nm and 1550 nm)
Output Power (dBm) Nominal  ≥ -12 dBm
Power Stability (dB) 2 ± 0.10
Launch Condition3 Not applicable
Length Measurement Range 4 up to 25 km
Length Measurement Uncertainty +/- 1 meter + 1% of length
1. 1. RMS for Fabry Perot lasers; FWHM for LEDs (typical). 
2. At constant temperature, relative to power level after 15-minute warm up, compliant for 8 hours.  
3. At 850 nm. Measured at the output of an encircled flux maintaining patch cord connected to the module’s output port. 
4. Length measurement is round trip time delay the cable under test.
Multi-Fiber Visual Fault Indicator (Source Port) 
Connector  MPO 16, pinned (when testing, this port will be connected to a Test Reference Cord which is available in MPO 12/16/24 and MMC 16/24 pinned and unpinned). 
Total Output Power >-5 dBm <0 dBm, continuous wave, at the 9/125 µm patch cord for single-mode source 
Operating Wavelength 635 nm nominal 
Output Modes Continuous, pulsed blink frequency (2 Hz to 3 Hz)
Laser Safety Class II CDRH
Optical Power Meter - Duplex Port (per module)
Specifications apply at 23°C, unless otherwise noted.
Parameter Single-mode
Input Connector Cylindrical ferrule duplex connectors (only one ferrule is measured at a time) 
Default Port Adapter LC Duplex 
Optional Port Adapters SC Duplex
Detector Type 1 mm InGaAs photodiode accommodates one fiber at a time
Supported Fiber Type Single-mode 9/125 µm
Calibrated Wavelengths 1310 nm, 1550 nm
Power Measurement Range +5 dBm to -45 dBm
Power Measurement Uncertainty1 < ± 0.35 dB
Power Measurement Linearity1,2 ±0.10 dB
Power Measurement Repeatability3 ±0.02 dB
Power Measurement  Reproducibility4 ±0.05 dB
Optical Connector Interface Accepts simplex LC or SC non-angled (UPC) and (APC) end face  
Re-calibration Period  1 year 
1. Under the following conditions: a. For calibrated wavelengths. Power level 10 µW (-20 dBm), continuous wave (CW) for absolute power. b. Divergent beam, NA = 0.20 for 50/125 µm and NA = 0.14 for 9/125 µm c. Ambient temperature 23° ± 3 °C d. FC/UPC connector with ceramic ferrule e. After a 15-minute warm-up f. Traceable to SI g. Based on calibration and metrology requirements.
2.For the measurement range -5 dBm to -40 dBm.
3. Maximum variation of power measurements when the measurement is repeated multiple times (i.e. 5 times) without disturbing the optical connector during 5 seconds at -30dBm MM and -12dBm SM.
4.Maximum variation of power measurements when the measurement is repeated multiple times (i.e. 5 times) when the optical connector is disconnected and reconnected between repeated measurements at -30dBm MM and -12dBm SM. 
Environmental Specifications (tested with module installed into Versiv mainframe) 
Operating Temperature  -10°C to +45°C  
Storage Temperature   -10°C to +60°C  
Operating Relative Humidity  0 % to 95 % noncondensing, 0°C to 35°C  
0 % to 70 %, 35°C to 45°C  
Vibration   Random, 2 g, 5 Hz to 500 Hz  
Shock   1-meter drop test  
Safety    IEC 61010-1  
Pollution Degree    2  
Altitude   Operating: 4 km  
Storage: 12 km  
EMC   IEC 61326-1  

 